High Capacity Digital Chilling/Heating Dry Baths

SKU: N/A Category:

Digital personal bench top incubators/chillers/freezers.  Large sample capacity.

Visit ACCESSORIES to choose sample blocks.

Manual

Data Sheet

Description

The completely solid-state large, Heavy-Duty, Digital, Electronic Chilling/Heating Dry Bath is versatile, reliable and easy to use. The IC30 has simple digital controls and a two line alphanumeric digital display that is backlit for easy reading.

The chilling/heating surface is a 5” (12.7 cm) square aluminum plate that is very flat for optimal contact with your sample. When unloaded, the plate surface will reach below 0°C in under two minutes. It will also heat to 37°C in approximately 3 minutes. This rate of chilling or heating may vary with the load on the plate. For instance, temperatures down to 4.0°C can be reached on a solid aluminum block in less than one hour. When insulated, these large blocks can be driven below 0°C. Temperature gradients from the center to the edge of any aluminum block mentioned will be less than 0.5°C at any temperature.

Sample covers are available for covering aluminum blocks.

Features

  • Energy-efficient Peltier design
  • Digital control to 1°C from -20°C to 100°C without sample block
  • Control at ambient
  • Built-in data logger
  • Count down timer (up to 30 days) with audible alarm and user settable Auto-Off
  • RS232 I/O port for data collection
  • Electronic calibration. Factory set, but user can set to any local standard
  • Small, compact size. Uses very little bench space
  • 12-volt DC operation. External power supply provided
  • 12-month warranty
  • UL, CSA and CE compliant

Applications

  • Unattended restriction digestions or ligations at elevated temperatures then reducing temperature to 4°C automatically to reduce non-specific nuclease digestion of target DNA
  • Automatically stopping reactions by having the unit reduce sample temperature after a specific reaction time
  • Producing denatured probes or single stranded DNA molecules by heating to 90°C/95°C for a given time and rapidly reducing temperature to 4°C to prevent renaturation
  • Automatic temperature profiles to grow bacteria at 37°C, then increasing temperature to induce events, and then lowering temperature to 4°C to prevent degradation
  • Maintaining 14°C for ligation reactions
  • Enzyme reactions and deactivations
  • Maintaining 17°C for storing oocytes
  • Storing reagents at 4C in 15, 50, 250, and 500ml centrifuge tubes
  • Storing samples at ice bucket temperatures without the mess
  • Incubating samples at 37°C in 96-well assay plates or in aluminum blocks holding 0.2, 0.5 and 1.5 ml centrifuge tubes, vials, and test tubes
  • Storing enzyme or DNA libraries at your workstation
  • Freezing and storing most any sample at your workstation

Full Product Specifications

Temperature
Range-10°C to 100°C IC35), -20C to 100C (IC35XT,),
Readability1°C
Accuracy±1°C
Stability±1°C
Sensor TypePlatinum RTD
Controller TypePID
Uniformity±0.5°C
Timer
Range00:01 to 30 days
Readability1 second
Audible AlarmYes, alarm sounds for 1 minute. Timer counts up until UP or DOWN key is touched
Programming
Programs Stored5
Individual Program Capacity10 Steps
Program Repeat1–99 times
Memory BackupYes, in CMOS
Data Logger
Sample times1 sec, 1 min or 5 minutes per data point
Capability7825 data points
Electrical
Heater/ChillerPeltier Module 100 watts IC35 & IC35XT
Operating VoltagesFrom 90 to 265 volts AC into universal power supply. 12 VDC output to chiller/heater module
Power Consumption100 watt:s IC35/IC35XT
Power SwitchYes
Chilling/Heating Module Dimensions
Width8.5" (21.6 cm) IC35 and IC35XT
Depth10" (25.4 cm) IC35 and IC35XT
Height4.0" (10.2 cm) IC35 and IC35XT
Power Supply Dimensions
Length6.5” (16.5 cm)
Height3.2” (8.1 cm)
Width2.2” (5.6 cm)
Weight (power supply & chiller/heater module)8 lbs (3.6 kg)